Slim Line Air
Handler 18K-36K
|
| FEATURES
--------------- |
| Modular
Design |
- White aluminum
construction.
- Modules
assembled for vertical or horizontal configurations.
- Interchangeable
panels for alternate supply and return air locations.
|
| Blower
Assembly Module |
- Permanent split
capacitor motors for quiet, efficient operation.
- Dual fan motor
speed selection.
- Fire retardant
plastic blower housings.
- Removable, fire
retardant air filters.
- Auxiliary ducts
for additional return air or fresh intake.
- Optional
auxiliary heating elements for additional heat capacity.
|
| Fan
Coil Assembly Module |
- Enclosed
insulated drain pan with threaded, dual drain connections for
complete condensate removal.
- Fully insulated
cabinetry.
- Interchangeable
3-way valve assembly, with air bleeder, for right or left side
application.
|
| Quality
Assurance |
- System matched
components assure full BTU rating.
- All units meet
or exceed applicable ABYC and U.S. Coast Guard regulations, CE
Directives and general Air Conditioning and Refrigeration
Industry (ARI) standards.
|
|

 |
| SPECIFICATIONS |
| Model |
AH18K-SL2 |
AH24K-SL2 |
AH30K-SL2 |
AH36K-SL2 |
|
| Capacity
(BTU/H)/(Kcal/H) |
18,000/14,536 |
24,000/6,048 |
30,000/7,560 |
36,000/9,072 |
| Voltage/Cycle/Phase |
230-208VAC/60
Hz/1o...220-200VAC/50Hz/1o |
230-208VAC/60
Hz/1o...220-200VAC/50Hz/1o |
230-208VAC/60
Hz/1o...220-200VAC/50Hz/1o |
230-208VAC/60
Hz/1o...220-200VAC/50Hz/1o |
| Amperage |
0.8 |
0.8 |
1.6 |
1.6 |
| GPM/(liters/min.) |
4.5/17.0 |
6.0/22.7 |
7.5/28.4 |
9.0/34.1 |
| CFM/(M^3/Hr.) |
600/1,019 |
750/1,274 |
1,000/1,698 |
1,200/2,038 |
| Auxiliary
Heating Element |
| Element
Size (KW) |
3.0 |
3.0 |
4.5 |
4.5 |
| Rating
(BTU/H)/(Kcal/H) |
10,245/2,582 |
10,245/2,582 |
15,368/3,873 |
15,368/3,873 |
| Amperage
(230VAC) |
13.0 |
13.0 |
19.5 |
19.5 |
| Max. Fuse
Size/Min. Circuit Ampacity |
| Without
Heating Element |
5.0/1.0 |
5.0/1.0 |
5.0/2.0 |
5.0/2.0 |
| With
Heating Element |
15.0/14.5 |
15.0/14.5 |
30.0/26.0 |
30.0/26.0 |
| Dimensions
(in/cm) |
| A
(Length) |
38.0/96.5 |
44.0/111.8 |
55.0/139.7 |
62.0/157.5 |
| B
(Depth) |
10.5/26.7 |
10.5/26.7 |
10.5/26.7 |
10.5/26.7 |
| C
(Height) |
22.0/55.9 |
22.0/55.9 |
22.0/55.9 |
22.0/55.9 |
| D
(Blower Module) |
10.5/26.7 |
10.5/26.7 |
10.5/26.7 |
10.5/26.7 |
| E (Fan
Coil Module) |
10.5/26.7 |
10.5/26.7 |
10.5/26.7 |
10.5/26.7 |
| F
(Discharge Flange) |
1.0/2.5 |
1.0/2.5 |
1.0/2.5 |
1.0/2.5 |
| G
(Discharge Opening-Depth) |
|
4.0/10.2 |
4.0/10.2 |
4.0/10.2 |
| H
(Discharge Opening-Length) |
30.0/76.2 |
36.0/91.4 |
47.0/119.4 |
54.0/137.2 |
|
| I
(Return Air Grille-height) |
8.0/20.3 |
8.0/20.3 |
8.0/20.3 |
8.0/20.3 |
| J
(return Air Grille-Length) |
37.0/94.0 |
43.0/109.2 |
54.0/137.2 |
61.0/155.0 |
| K
(Auxiliary Return/Fresh Air Duct) |
3.0/7.6 |
3.0/7.6 |
3.0/7.6 |
3.0/7.6 |
| L (Water
Valve Assembly-Depth) |
4.25/10.8 |
4.25/10.8 |
4.25/10.8 |
4.25/10.8 |
| M (Water
Valve Assembly-Length) |
7.75/19.7 |
7.75/19.7 |
7.75/19.7 |
7.75/19.7 |
| N (Water
Valve Assembly-Height) |
9.90/25.1 |
9.90/25.1 |
9.90/25.1 |
9.90/25.1 |
| O
(Circulation Water Inlet/Outlet) |
0.5"
FPT brass with 0.625" HB brass |
0.5"
FPT brass with 0.625" HB brass |
0.5"
FPT brass with 0.625" HB brass |
0.5"
FPT brass with 0.625" HB brass |
| P
(Condensate Drains) |
2
@ 0.625" ox 2" long pipe |
2
@ 0.625" ox 2" lon |
2
@ 0.625" ox 2" lon |
2
@ 0.625" ox 2" long pipe |
| Weight
(lbs/kg) |
68/31 |
70/32 |
88/40 |
90/41 |
|
| *
Auxiliary heating elements are optional and may be ordered factory
installed or as retrofit components. Above sizes are maximum values
for each model. |
| **
Dimensions are for vertical configurations. For horizontal
configurations, reverse depth (B) and height(C) dimensions. |
| ***
Remote mounted water valve assemblies are available. Smaller
elements may be applied to all units except the AH6K/9K-SL2 units. |
|
| Installation
Guidelines for slim line air handler 18K-36K |
|
When choosing the proper model Slim
Line Air Handler, primary consideration should be given to
calculated BTU loads and available power supply.
Slim Line Series air handlers are
designed to be direct-discharge or ductable units. Air flow can be
supplied to more than one area through the use of properly sized
plenums, transitions and ductwork. The SL2 configuration allows for
installation in tight areas (shipside panels, narrow bulkhead
spaces, short overheads, etc.) in either horizontal or vertical
positions.
Securely fasten the slim line air
handler units to a solid level surface using the four (4) mounting
holes provided in the base. The supply air outlet must be sealed
properly either through cabinetry for direct-discharge, or into a
plenum for a ductable discharge. All ductwork is to be routed as
smooth and direct as possible. Any flexible ducting is to be secured
every 48" (minimum) to prevent movement while the vessel is
under operation. Trim off excess ducting before making final
connections.
The return air inlet(s) must be
properly sized and located to allow adequate air flow into the air
handler. The SL2 series air handlers have factory installed,
removable filters to trap dust and other airborne particles. Return
air inlets should not be located in such a way as to allow the
supply air stream to blow directly into its opening. This will cause
"short cycling" of the unit, resulting in poor or
inadequate performance. |
The supply air grille(s) must be sized
and located to allow for proper air circulation within the cabin
area(s). Grille locations close to the ceiling, or directed upward,
provide the best air circulation. Undersized grilles and plenums,
along with any crushed or kinked ductwork, will result in poor or
inadequate air performance.
Both condensation drain lines must be
connected to the air handlers' two (2) drain pan spuds using
reinforced flexible hose (5/8") and clamps. The drains may be
teed together, providing there is a minimum drop of 2" from the
drain pan to the tee fitting. The drain line must be routed
downwards to a proper sump or overboard discharge. Properly secure
the drain lines to prevent movement or lifting during vessel
operation. Check the drains upon completion by pouring two (2)
quarts of water into the drain pan. NOTE: Condensation drain lines
may need to be insulated when located overhead in lockers to prevent
sweating of the line , which could cause water damage.
Water connections from the circulation
circuit to the unit are to be reinforced flexible hose and double
clamped, direction of clamps should be reversed. Attach the hose to
the 5/8" hose barb fittings on the water inlet and outlet of
the unit. All hose, pipe and connections must be insulated properly
to prevent condensation. Use approved closed cell tube insulation
(1/2" minimum) on the hose, and foam tape on the fittings (5-6)
wraps.
All wiring must be sized according to
marine design standards. Only stranded, tinned copper wire is to be
used. All electrical connections to the air handler are to be made
inside the electrical junction boxes provided on the assembly. All
units must be properly grounded. |
 |